Skip to main content

【Supercomputer】Maintenance work performed during the scheduled maintenance

publication date :

The Supercomputer Systems have been updated upon completing the maintenance work performed from September 23 to 26, 2024.

  1. Installation of New Software Versions
  2. Disabling the GPU System Processor (GSP) Firmware

1. Installation of New Software Versions

The table below shows the new software versions installed after the last maintenance.

For details on how to use each software, please refer to the following web pages.

SoftwareNew VersionModulefileRemarks
Intel oneAPI
Intel oneAPI for NVIDIA GPU 2024.0 intel/2024.0-gpu System G
2023.2 intel/2023.2-gpu System G
ISV Applications
LS-DYNA R15.0.2 ls-dyna/R15.0.2 System B/C/G
File Transfer Server
Archaea tools 1.5.6_12 -

Archaea dialog 1.2.1_10 and Archaea tools 1.5.6_12 for clients are now available.Please update accordingly if you use.

2. Disabling the GPU System Processor (GSP) Firmware

System G (gardenia) occasionally fails to recognize the GPU correctly. In order to improve this issue, the GPU System Processor (GSP) firmware was disabled in the scheduled maintenance in September.


Inquiry E-mail:consult
Image
icon_atmark
kudpc.kyoto-u.ac.jp
Inquiry Form